Resetting the lamp timer, Regarding the lamp – Sharp DT-400 User Manual

Page 58

Advertising
background image

-58

4

Remove the lamp unit.

• Loosen the two securing screws from

the lamp unit. Hold the lamp unit by the
handle and pull it in the direction of the
arrow. At this time, keep the lamp unit
horizontal and do not tilt it.

5

Insert the new lamp unit.

• Press the lamp unit firmly into the lamp

unit compartment. Fasten the securing
screws.

6

Replace the lamp unit cover.

• Align the lamp unit cover and slide it to

close. Then tighten the user service
screw to secure the lamp unit cover.

Info

• If the lamp unit and lamp unit cover are not

correctly installed, the power will not turn
on, even if the power cord is connected to
the projector.

Resetting the Lamp Timer

Reset the lamp timer after replacing the lamp.

Info

• Make sure to reset the lamp timer only

when replacing the lamp. If you reset the
lamp timer and continue to use the same
lamp, this may cause the lamp to become
damaged or explode.

1

Connect the power cord.

• Plug the power cord into the AC socket

of the projector.

2

Reset the lamp timer.

• Press

,

,

, \

\

\

\

\,

and |

|

|

|

| on the

projector in order, and then press

on

the projector.

• “LAMP 0000H” is displayed on the lower

left of the screen, indicating that the lamp
timer is reset.

Regarding the Lamp

Securing screws

Handle

User service screw
(for lamp unit cover)

AC socket

\

/

|

buttons

ON button

ENTER button

UNDO button

INPUT button

DT400_E_P53_60.p65

04.10.18, 1:26 PM

58

Advertising