PAN/TILT/ZOOM Set-up

(1) You will see the next window, if you click "P/T/Z" icon in administration mode.

(2) Device

To control PAN/TILT/ZOOM/FOCUS, connect the PAN/TILT/ZOOM/FOCUS camera & controller to the

+, - terminals of RS-485 on the rear of your web transmitter. For further information, refer to Chapter 3.

"Connecting to PAN/TILT/ZOOM/FOCUS Camera & Controller".

Here are the supported PAN/TILT/ZOOM/FOCUS camera & controller.

Smart Dome Camera & Controller, made by Samsung Electronics

P Protocol Dome Camera and Receiver, made by PELCO

CPU Receiver, made by Sungjin Electronics

(3) Baud Rate

Set up appropriate Baud Rate depending on the type of controller.

(4) Data Bit

Select Data Bit from either 7Bit or 8Bit, depending on the type of controller.

(5) Stop Bit

Select Stop Bit from either 1 Bit or 2 Bit, depending on the type of controller.

(6) Parity Bit

Select Parity Bit from Odd, Even, or None, depending on the type of controller.

(7) Camera Identity

Maximum of 4 PAN/TILT/ZOOM/FOCUS controllers may be connected. When connecting more than

one controller, you must assign an ID for each controller. Please, refer to the controller manual for its ID.

If you have a device other than Pan/Tilt/Zoom/Focus controller that is currently
supported, contact your vendor.