Contents

Chapter 3 — Hardware Setup

Switch SW 2

(cont’d.)

Function

Global Data
Base Control

Enables the 1560-MBP
to automatically gather
the Control Word and
Speed Reference
values from the
selected Host Global
Database.

When enabled, the
1560 will use two
words from the global
database based on the
selected Modbus Plus
address (SW1-1 to 6).

When disabled, the
Host must write into
1560 unit's Modbus
register table at
addresses 40001/2 to
write the Control word
and speed reference
values

Details

Description

SW2-7
Off = Disable Global Data
Base Control
On = Enable Global Data
Base Control

Important

A maximum of 16 1560-MBP

units can be enabled in the

Global Control Mode on one

PLC network. These 16 units

must be addressed within one

of the following ranges:

1 to 16
17 to 32
33 to 48
49 to 64

Selects the Modbus
Plus Address for the
1560-MBP unit. Each
node must have a
unique address. Note
that the addresses will
be one higher than the
binary value selected by
the dip switches.

It is recommended that
address 1 not be used
to avoid possible
confusion when using a
local default address of
1 at a controller node
programming panel.

Modbus Plus
Address
(1560-MBP
unit address)

SW2-1 to 6

1

Address Bit 0

Value = 1

2

Address Bit 1

Value = 2

3

Address Bit 2

Value = 4

4

Address Bit 3

Value = 8

5

Address Bit 4

Value = 16

6

Address Bit 5

Value = 32

6 5 4 3 2 1 Address
off off off

off

off

off

1

off off off

off

off

on

2

off off off

off

on

off

3

off off off

off

on

on

4

off off off

on off

off

5

off off off

on off

on

6

off off off

on on

off

7

off off off

on on

on

8

off off on

off

off

off

9

off off on

off

off

on

10

off off on

off

on

off

11

off off on

off

on

on

12

off off on

on off

off

13

off off on

on off

on

14

off off on

on on

off

15

off off on

on on

on

16

off on off

off

off

off

17

off on off

off

off

on

18