HDS-X5800

2-4. Cleaning Filter

n
If dust adheres to the filter, the ventilation holes are
blocked and airflow inside the machine is also blocked so
that the temperature inside the unit increases.
Clean the filter periodically once every two months.

1.

Remove the front panel. (Refer to Section 2-2.)

2.

Remove the dust from the filter using a vacuum.
m
. If the filter is very dusty, it is recommended to

remove the filter from adhesive tape and wash it in
water.

. If the filter is washed in water, dry it completely.

3.

Install the front panel. (Refer to Section 2-2.)

Front panel

Filter (PS)

Filter (L)

Adhesive tape

Adhesive tape

Adhesive tape

Adhesive tape

Adhesive tape

2-5. CPU Battery

A lithium battery is mounted on the CPU-339 board for
backing up RAM and for driving internal watch while the
power is turned off.
Replace the battery before the replacement time shown
below comes.

Status of usage of

Replacement time

this machine

The battery has never

Non power-on period of this

been replaced since

machine is shorter than approx. 3

purchase of this machine.

years.
(Because consumption of battery
has started already at the time of
purchase of this machine.)

The battery is replaced by

Non power-on period of this

the new battery last time.

machine is approx. 3 years.

This machine has been

Period of usage of this machine

used with always power-on. is shorter than 5 years.

(Because the battery life is 5
years and the consumption of the
battery has already started at the
time of purchase of this machine.)

Refer to Maintenance Manual for the replacement proce-
dure of the CPU battery.