Wiring to power supply module

[1] JW-1PU

· Open the terminal block cover, fasten with the screw with torque of less than 12kg·cm.

· A maximum of three halt output lines can be connected serial. To use more than three sets, use

a relay for interconnection.

In case of 100 VAC input

In case of using DC output module, connect the AC relay in the halt output line and insert the

contact with the emergency stop circuit.

In case of 200 VAC input

· In case of using 200 VAC, switched to the 200 V side in terminal block of power supply module.

· If 200 V is added with the clip connected to the 100 V side, it may damage the power supply

module.

SHORT
200 VAC

100 VAC
or 200 VAC

SHORT
100 VAC

GND

The coil rating must conform to the power supply voltage.

In case of 100 VAC input Terminal block cover

Terminal block
cover

DC relay

halt output
line

SHORT
200 VAC

200 VAC

input

SHORT
100 VAC

GND

Halt output internal circuit