8

·

12

From the previous page

Set LG (shield ground) switch

· For communication lines, use a coaxial cable.

· As coaxial cable is an unbalanced circuit,

ground its shield by turning “ON” the shield

ground switch.

• Make sure to provide a class-3 grounding for the GND terminal of the power supply module.

Without grounding the power supply module, the JW-20CM cannot become conductive with the

ground after turning “ON” the shield ground switch. (See page 7·2.)

• Prior to any electric welding around the JW-20CM, take out the coaxial cable from the JW-20CM.

While the coaxial cable is connected to the JW-20CM, any electric welding nearby the JW-20CM

will cause the welding current to the JW-20CM and may damage part of its circuit pattern.

To the next page

Coaxial cable

Turn “ON” shield ground
switch

Turn “ON” shield ground
switch

Turn “ON” shield
ground switch

Rack etc.

JW-20CM

JW-20CM has a fuse element here.

Electric welder

Note:

Coaxial cable

Wrap around current

Note: In case enough

conductivity is not
established.

FG

JW-20CM

Turn “ON” shield
ground switch

Advertising