Operational synchronous

When more than one JW-20CM is installed while using the remote I/O function, set only one module

as “operational synchronous.” When a link module ZW-10CM or JW-10CM is used for remote I/O, the

JW-20CM should be set as “operational asynchronous.”

a. When operation interval (one scan) of the master station PC is longer than data transfer

time of the remote I/O:

b. When operation interval (one scan) of the master station PC is shorter than data transfer

time of the remote I/O:

A waiting time is provided after the PC process to match with end timing of the data transfer

process of the remote I/O so that the remote I/O can synchronize with the PC scan cycle.

Operational asynchronous

The special I/O module can not be used with the remote I/O slave module as the special I/O module

cannot synchronize with the master station PC for data exchange.

a. When operation interval (one scan) of the master station PC is longer than data transfer

time of the remote I/O:

Same as operational synchronous above.

b. When operation interval (one scan) of the master station PC is shorter than data transfer

time of the remote I/O:

Data exchange with the buffer memory

I/O processing at PC side

PC operation time

Remote I/O data transfer processing

I/O processing at PC side

PC scan cycle

Waiting time

Data exchange with the buffer memory

I/O processing at PC side

PC operation time

Remote I/O data
transfer processing

I/O processing
at PC side

PC scan cycle

Remote I/O data
transfer processing

Data exchange with the buffer memory

I/O processing at PC side

PC operation time

Remote I/O data transfer processing

Remote I/O data transfer processing

I/O processing
at PC side

PC scan cycle

PC operation time

PC operation time