8

·

17

From the previous page

Set LG (shield ground) switch

· For communication lines, use a coaxial cable.

· As coaxial cable is an unbalanced circuit,

ground its shield by turning “ON” the shield

ground switch.

• Make sure to provide a class-3 grounding for the GND terminal of the power supply module.

Without grounding the power supply module, the JW-20CM cannot become conductive with

the ground after turning “ON” the shield ground switch. (See page 7·2.)

• Prior to any electric welding around the JW-20CM, take out the coaxial cable from the JW-

20CM. While the coaxial cable is connected to the JW-20CM, any electric welding nearby the

JW-20CM will cause the welding current to the JW-20CM and may damage part of its circuit

pattern.

To the next page

Coaxial cable

Turn “ON” shield ground
switch

Turn “ON” shield ground
switch

Coaxial cable

JW-20CM

Turn “ON”

shield ground

Rack etc.

Electric welder

Note: In case enough

conductivity is not
established.

JW-20CM

Turn “ON”

shield ground

JW-20CM has a
fuse element here

Wrap around current

Note:

FG

FG

Advertising