Setting contents of slave station parameters

When the JW-20CM is used as a slave station, set the following items for parameters.

1 Set only any of JW50/70/100 or JW50/70H/100H is used as PC, and using SEND/RECEIVE

instruction.

2 Set only any of JW50/70/100 or JW50/70H/100H is used as PC, and using the memory capacity

save function.

to

correspond to numbers in the next page.

E0

01

00

80

e

1

to

e

n

i

1

to

i

n

Setting item

Setting time-out item of SEND/
RECEIVE instruction

007500

to

007577

007730

to

007733

007734

to

007737

00

00

00

V5

Number of receiving bytes of
relay link in memory capacity
save function

Set the number of bytes by decimals. (0 to 64)
· If 0 is set, the number of bytes will be the same
as the number of the sending bytes which is set
in the master station

007720
007721

00

V5

Number of receiving bytes of
register link in memory
capacity save function

Set the number of bytes by decimals. (0 to 512)
· If 0 is set, the number of bytes will be the same
as the number of the sending bytes which is set
in the master station

007722
007723

00

00

00

00

V2

Whether the station number
information should be output
or not

Top address of flag area
(communication and PC
operation condition monitor
flag)

Store the number of own station in the data memory

when setting on 01

(H)

. (storage area of 1 byte follows

flag area of 24 bytes, valid when 007767

(8)

is 80

(H)

)

Lower of file address

Upper of file address

File number

Flag output (Yes: 80

(H)

No: 00

(H)

)

Settable detection interval with 100 ms pitch

00

(H)

: Stop remote I/O operation

01

(H)

: Start remote I/O operation

80

(H)

: Writing to the EEPROM, stop operation

81

(H)

: Writing to the EEPROM, start operation

08

(H)

: Initialize the parameter

007763

00

007771

007777

01

007764

007765

007766

007767

Select system of each channel
in SEND/RECEIVE function

Select instruction system or data memory starting
system in CH0 to CH3

V5

007700

to

007703

Top addresses in communi-
cation information storage area
when using data memory start-
ing system of SEND/RECEIVE
functions

V5

007710

to

007713

Initial value: 01E0

(H)

007767

(8)

( 0740)

h

1

to

h

n

91

Setting PC model of each
station in SEND/RECEIVE
function

007600

to

007677

Address

(8

)

Contents

Initial

value

(H)

Corresponding

signs on pages

11·7 and 11·8

1

2

For using SEND/RECEIVE instruction, set the
time out time by decimal.
[001 (0.1 sec..) to 255 (25.5 sec.)]

91

(H)

: The PC is JW type and ZW-20CM has

JW mark or JW-20CM or JW-22CM

81

(H)

: The PC is ZW type and ZW-20CM

has JW mark or JW-20CM.

00/81

(H)

:ZW-20CM without JW mark

Setting by file number and file address.
· Setting within communication information
storage area (64 bytes)

File 0: 000000 to 015777

(8)

File 1 to 7: 000000 to 177777

(8)

Top address of relay link
area

Set by file number and file address.
(See page 13·20 and 13·21)

f

1

to

f

n

Top address of register link
area

Set by file number and file address.
(See page 13·20 and 13·21)

g

1

to

g

n

V5

V5

Communication error
detection interval

Writing to the EEPROM,
start operation/stop setting