Symptom

Action

The

power-control

button

does

not

work,

and

the

reset

button

does

work

(the

server

does

not

start).

Note:

The

power-control

button

will

not

function

until

20

seconds

after

the

server

has

been

connected

to

ac

power.

1.

Make

sure

that

the

power-control

button

is

working

correctly:

a.

Disconnect

the

server

power

cords.

b.

Reconnect

the

power

cords.

c.

(Trained

service

technician

only)

Reseat

the

operator

information

panel

cables,

and

then

repeat

steps

1a

and

1b.

v

(Trained

service

technician

only)

If

the

server

starts,

reseat

the

operator

information

panel.

If

the

problem

remains,

replace

the

operator

information

panel.

v

If

the

server

does

not

start,

bypass

the

power-control

button

by

using

the

force

power-on

jumper

(see

“System-board

switches

and

jumpers”

on

page

30).

If

the

server

starts,

reseat

the

operator

information

panel.

If

the

problem

remains,

replace

the

operator

information

panel.

2.

Make

sure

that

the

reset

button

is

working

correctly:

a.

Disconnect

the

server

power

cords.

b.

Reconnect

the

power

cords.

c.

(Trained

service

technician

only)

Reseat

the

EasyLED

panel

cable,

and

then

repeat

steps

1a

and

1b.

v

(Trained

service

technician

only)

If

the

server

starts,

replace

the

EasyLED

panel.

v

If

the

server

does

not

start,

go

to

step

3.

3.

Make

sure

that:

v

The

power

cords

are

correctly

connected

to

the

server

and

to

a

working

electrical

outlet.

v

The

type

of

memory

that

is

installed

is

correct.

v

The

DIMMs

are

fully

seated.

v

The

LEDs

on

the

power

supply

do

not

indicate

a

problem.

v

The

microprocessors

are

installed

in

the

correct

sequence.

4.

Reseat

the

following

components:

a.

DIMMs

b.

(Trained

service

technician

only)

Power

switch

connector

c.

(Trained

service

technician

only)

Power

backplane

5.

Replace

the

components

listed

in

step

4

one

at

a

time,

in

the

order

shown,

restarting

the

server

each

time.

6.

If

you

just

installed

an

optional

device,

remove

it,

and

restart

the

server.

If

the

server

now

starts,

you

might

have

installed

more

devices

than

the

power

supply

supports.

7.

See

“Power-supply

LEDs”

on

page

34.

8.

See

“Troubleshooting

tables”

on

page

144.