Lenovo RD210 User Manual

Page 37

Advertising
background image

Table

2.

EasyLED

diagnostics

(continued)

v

Follow

the

suggested

actions

in

the

order

in

which

they

are

listed

in

the

Action

column

until

the

problem

is

solved.

v

See

the

parts

listing

in

the

Hardware

Maintenance

Manual

to

determine

which

components

are

customer

replaceable

units

(CRU)

and

which

components

are

field

replaceable

units

(FRU).

v

If

an

action

step

is

preceded

by

“(Trained

service

technician

only),”

that

step

must

be

performed

only

by

a

trained

service

technician.

LED

Description

Action

OVER

SPEC

(Continued)

The

power

supplies

are

using

more

power

than

their

maximum

rating.

If

the

12V

channel

E

error

LED

is

lit,

complete

the

following

steps:

1.

Turn

the

server

off

and

disconnect

the

power

from

the

server.

2.

Remove

the

PCI

riser

card

from

PCI

riser

connector

2

and

the

microprocessor

in

socket

2.

3.

Restart

the

server

to

see

if

the

problem

remains.

4.

Reinstall

each

device

that

was

removed

in

step

b

one

at

a

time,

starting

the

server

each

time,

to

isolate

the

failing

device.

5.

Replace

any

failing

device.

6.

(Trained

service

technician

only)

Replace

the

system

board,

if

the

problem

remains.

If

the

12V

AUX

channel

error

LED

is

lit,

complete

the

following

steps:

1.

Turn

the

server

off

and

disconnect

the

power

from

the

server.

2.

Remove

all

PCI

Express

cards,

all

PCI

riser

cards,

the

operator

information

panel,

and

the

Ethernet

daughter

card

(if

installed).

3.

Restart

the

server

to

see

if

the

problem

remains.

4.

Reinstall

each

device

that

was

removed

in

step

b

one

at

a

time,

starting

the

server

each

time,

to

isolate

the

failing

device.

5.

Replace

any

failing

device.

6.

(Trained

service

technician

only)

Replace

the

system

board,

if

the

problem

remains.

LOG

An

error

occurred.

Check

the

IMM

System

Event

log

and

the

system-error

log

for

information

about

the

error.

Replace

any

components

identified

in

the

error

logs.

LINK

Reserved.

PS

Power

supply

1

or

2

has

failed.

1.

Make

sure

that

the

power

supplies

are

seated

correctly.

2.

Remove

one

of

the

power

supplies

to

isolate

the

failed

power

supply.

3.

Replace

the

failed

power

supply.

Chapter

4.

Server

controls,

LEDs,

and

power

21

Advertising
This manual is related to the following products: