Removing, Installing, Serveraid-br10i – Lenovo RD210 User Manual

Page 80: Sas/sata, Controller

Advertising
background image

Note:

If

there

is

a

gap

between

the

DIMM

and

the

retaining

clips,

the

DIMM

has

not

been

correctly

inserted;

open

the

retaining

clips,

remove

the

DIMM,

and

then

reinsert

it.

11.

Reconnect

the

power

cord

and

any

cables

that

you

removed.

12.

Replace

the

cover

(see

“Removing

and

replacing

the

cover”

on

page

43).

13.

Turn

on

the

peripheral

devices

and

the

server.

Removing

and

installing

the

IBM

ServeRAID-BR10i

SAS/SATA

Controller

To

remove

and

install

the

IBM

ServeRAID-BR10i

SAS/SATA

Controller,

complete

the

steps

in

this

section.

Removing

the

IBM

ServeRAID-BR10i

SAS/SATA

Controller

To

remove

the

IBM

ServeRAID-BR10i

SAS/SATA

controller

from

the

system

board,

complete

the

following

steps:

1.

Read

the

safety

information

in

“Safety”

on

page

vii

and

“Installation

guidelines”

on

page

39.

2.

Turn

off

the

server

and

peripheral

devices

and

disconnect

the

power

cords.

Note:

When

you

disconnect

the

power

source

from

the

server,

you

will

lose

the

ability

to

view

the

LEDs

because

the

LEDs

will

not

be

lit

with

the

power

source

removed.

Before

disconnecting

the

power

source,

make

a

note

of

which

LEDs

are

lit,

including

the

LEDs

that

are

lit

on

the

operation

information

panel,

the

EasyLED

panel,

and

LEDs

that

are

lit

inside

the

server

on

the

system

board;

then,

see

“EasyLED”

on

page

157

for

information

on

how

to

solve

the

problem.

3.

Remove

the

cover

(see

“Removing

and

replacing

the

cover”

on

page

43).

4.

Disconnect

the

signal

cables

that

are

attached

to

the

drive

backplane

from

the

connectors

on

the

controller.

5.

Grasp

the

SAS/SATA

controller

near

the

end

next

to

the

power-supply

cage

and

press

the

black

plastic

tab

(next

to

the

power

supply)

that

is

holding

the

controller

in

place

toward

the

power

supply.

6.

Pull

up

on

the

SAS/SATA

controller

until

the

RAID

riser

card

assembly

disengages

from

the

connector

on

the

system

board.

1

USB

embedded

connector

2

RAID

controller

connector

3

Riser

card

error

LED

4

SAS/SATA

RAID

riser

card

7.

Grasp

the

SAS/SATA

controller

and

pull

it

out

of

the

connector

on

the

RAID

riser

card

assembly.

64

ThinkServer

RD210

Types

3795,

3796,

3818,

and

3819:

Installation

and

User

Guide

Advertising
This manual is related to the following products: