Server power features, Turning on the server, Server – Lenovo RD210 User Manual

Page 51: Power, Features, Turning

Advertising
background image

Table

5.

System

pulse

LEDs

(continued)

LED

Description

Action

IMM

heartbeat

IMM

heartbeat

boot

process.

The

following

steps

describe

the

different

stages

of

the

IMM

heartbeat

sequencing

process.

1.

When

this

LED

is

blinking

fast

(approximately

4Hz),

this

indicates,

that

the

IMM

code

is

in

the

loading

process.

2.

When

this

LED

goes

off

momentarily,

this

indicates

that

the

IMM

code

has

loaded

completely.

3.

When

this

LED

goes

off

momentarily

and

then

starts

blinking

slowing

(approximately

1Hz),

this

indicates

that

IMM

is

fully

operational.

You

can

now

press

the

power-control

button

to

power-on

the

server.

4.

If

this

LED

does

not

blink

within

30

seconds

of

connecting

a

power

source

to

the

server,

complete

the

following

steps:

a.

(Trained

service

technician

only)

use

the

IMM

recovery

jumper

to

recover

the

firmware

(see

“System-board

switches

and

jumpers”

on

page

30).

b.

(Trained

service

technician

only)

replace

the

system

board.

Server

power

features

When

the

server

is

connected

to

an

ac

power

source

but

is

not

turned

on,

the

operating

system

does

not

run,

and

all

core

logic

except

for

the

service

processor

(the

Integrated

Management

Module)

is

shut

down;

however,

the

server

can

respond

to

requests

to

the

service

processor,

such

as

a

remote

request

to

turn

on

the

server.

The

power-on

LED

flashes

to

indicate

that

the

server

is

connected

to

ac

power

but

is

not

turned

on.

Turning

on

the

server

Approximately

5

seconds

after

the

server

is

connected

to

ac

power,

one

or

more

fans

might

start

running

to

provide

cooling

while

the

server

is

connected

to

power

and

the

power-on

button

LED

will

blink

quickly.

Approximately

1

to

3

minutes

after

the

server

is

connected

to

ac

power,

the

power-control

button

becomes

active

(the

power-on

LED

will

blink

slowly),

and

one

or

more

fans

might

start

running

to

provide

cooling

while

the

server

is

connected

to

power.

You

can

turn

on

the

server

by

pressing

the

power-control

button.

The

server

can

also

be

turned

on

in

any

of

the

following

ways:

v

If

a

power

failure

occurs

while

the

server

is

turned

on,

the

server

will

restart

automatically

when

power

is

restored.

Chapter

4.

Server

controls,

LEDs,

and

power

35

Advertising
This manual is related to the following products: