Lincoln Impinger Conveyor Oven Series 1000 User Manual

Page 29

Advertising
background image

Impinger I -–1000 Series Service Manual - International

29

Burner Ignitor

Check the burner ignitor head for any obstructions,

also check for frayed or broken wire, any type of

damage to spark gap (.100 in. 2.5 mm) If there is

visible damage, replace ignitor assembly.

Pilot flame but no main

flame

Spark Ignitor (Flame Sensor)

(There should be a visible pilot flame at this time).

NOTE: The Honeywell Ignition Control uses the

spark ignitor as the flame sensor. If spark

continues, check for proper ground connections at

Ignition Control. Check pilot orifice for any partial

blockage. If the above checks OK, replace ignition

control. If spark stops when pilot is lit, check for 24

VAC across M.V. - M.V/ P.V. terminals, if voltage is

not present, replace ignition control. If voltage is

present at terminals M.V. - M.V./P.V., the indicator

light on the control panel should be on, verify that

the main valve has opened, connect manometer to

manifold gas pressure tap (located on the back

side of the gas valve). If no gas is present, replace

gas valve.

Temperature Control Valve

(Robert Shaw)

Check for gas supply at temperature control. Check

for temperature control set above 300°F.

Red Indicator Light is

on, but no main

flame

(For ovens with

mechanical

thermostat)

Main Orifice

Check for blockage of main orifice. If there is no

blockage to the main orifice, replace the

temperature control.

(For ovens with

Electronic

Temperature Control)

Temperature Control

Potentiometer

Check for 120 VAC across L1 and L2on

temperature control board. Potentiometer (1000

ohm,1 turn) WITH POWER OFF: check ohms

across red and black leads, the ohm reading

should be 0 to1000 ohms as the dial is turned.

From green to red, the reading should be 1000

ohms steady throughout the full turn of the dial.

NOTE: Ovens S/N Q18037 and above, the potentiometer is internal to temperature control. Proceed to next

component.

Thermocouple Probe

Remove thermocouple leads from the temperature

control board, and measure the millivolt output of

these leads. Refer to chart on page 59 in the

adjustment section for proper readings.

Temperature Control

Turn temperature control dial to full "on" position.

Measure for 120 VAC across terminals "N.O." and

"L2", if voltage is not present; replace control.

Solenoid Valve

If voltage is present at terminals "N.O." and "L2",

check for voltage at solenoid valve. If voltage is

present, listen for valve to open and close. Also,

check for opens and shorts in coil. If solenoid valve

is defective, replace

Intermittent Heating

Both the main fan motor and burner blower motor

are equipped with thermo-protection and will cease

to operate when not cooled properly. This can

cause the units to cycle on and off intermittently.

Also, most of the problems listed under "oven will

not heat" can cause intermittent failures.

For continuing intermittent problems, a series of test lights may be made and installed in

the ovens. The lights will allow the customer to advise the service technician a trouble code when

the oven fails.

The lights should be connected in the following manner:

Light#l attached in 120VAC line after Air Pressure Switch.

Light#2 attached after 120VAC contacts of Burner Motor Relay (or, refer to Bulletin #028

for Relay Removal).

Light#3 in 24VAC Burner Transformer Secondary.