Impinger I -–1000 Series Service Manual - International

46

TROUBLESHOOTING / GAS OVENS 1033, 1034, 1046, 1047

SYMPTOM

POSSIBLE CAUSE

EVALUATION

Incoming Power Supply

Check breaker/reset if required. Call Power

Company if needed. In these ovens, there is a

control circuit step-down transformer. This

transformer steps down supply voltage to 120 VAC.

If main fan will not run, the secondary of this

transformer must be checked for 120 VAC output.

Check specific oven model schematic for circuit

location.

Transformer Fuse

Check and/or replace.

Fuseholder

Check and/or replace.

Fan Switch

Check continuity between switch terminals.

Oven Start Relay

Check for 120 VAC to the relay coil. If voltage is not

present, trace wiring back to the fan switch. If

voltage is present, check to insure contacts are

closing.

20 Minute Time Delay

Check for 120 VAC at terminal #1 to neutral on the

20-minute timer. If no voltage is present, trace

wiring back to the power supply. If voltage is

present at terminal #1, check for 120 VAC at

terminal #2 to neutral. If no voltage is present, and

the oven start relay is closed, replace the 20-

minute timer.

Oven Fan Relay

Check for 120 VAC to coil of the oven fan relay. If

no voltage is present, trace wiring back to terminal

#2 of the 20-minute timer. Check for 120 VAC at

terminals #2 and 6 of the relay, if no voltage is

present, trace wiring back to the power supply. If

voltage is present at the relay coil, check to insure

the contacts are closing.

Fan Fuse

Check, replace if necessary.

Fuseholder

Check, replace if necessary.

Capacitor

Check for opens, shorts, or grounds.

Oven fan will not run

Motor

Check for opens, shorts, or grounds. WITH

POWER OFF: turn the fan blade to check for

locked rotor.

20 Minute Time Delay

Check for 120 VAC at terminal #2 to neutral while

oven is "on". Turn off the main fan switch, 120 VAC

should continue to be present for 20 minutes. If

voltage is not present for approx. 20 minutes,

replace the timer.

No main fan cool down

Oven Fan Relay

Check if relay is operating and that the contacts

remain closed during the 20 minute cool down.

Oven Start Relay

Contacts should open when main fan switch is

turned off.

20 Minute Time Delay

120 VAC at terminal #2 should discontinue

approximately 20 minutes after main fan is

switched off. If the oven start relay contacts are

open, and the voltage continues at terminal #2 of

the 20 minute timer, replace the timer.

Main fan runs after 20

minute cool down

Oven Fan Relay

Check to insure that the contacts are opening after

the coil is de-energized.

No control box cooling Fan Switch Oven Start

Relay20 Minute Time Delay

Oven Fan Relay Cooling

Fans

(SEE MAIN FAN WILL NOT RUN) 120 VAC should

now be at this motor. If voltage is present, check

motor for shorts, opens, or grounds. WITH POWER

OFF: check for locked rotor.