Impinger I -–1000 Series Service Manual - International

50

Main Flame will not

stay lit

Flame Monitor

(There should be a visible main flame at this time.)

To check for flame monitor operation, connect a

digital volt meter (capable of measuring D.C. micro

amperes) between the flame sensor and terminal

#15 on the flame monitor. The flame monitor

requires a minimum of 4 micro amp. D.C. for proof

of flame. If these readings are not achieved,

replace sensor assembly. Also check for any type

of damage to flame sensor wire and connections.

If the reading is above the minimum required, and

the flame monitor will not supply 220 VAC to the

relay coil, replace the flame monitor.

Intermittent Heating

As Follows

Both the main fan motor and burner blower motor

are equipped with thermal protection and will cease

to operate if overheating occurs. This can cause

the units to cycle on and of intermittently. This may

be caused by improper ventilation. Also, most of

the problems listed under "oven will not heat" can

cause intermittent failure.

Conveyor Switch

Check for 120 VAC to conveyor switch. If no

voltage is present, trace wiring back to the power

supply. WITH POWER OFF: Check continuity

between switch terminals

Conveyor Fuse(3A)

Check, replace if necessary.

Fuseholder

Check, replace if necessary.

Conveyor Control

Check for 120 VAC supply to primary (Stepper)

Transformer of transformer, if voltage is not

present, trace wiring back to the fuseholder. If

voltage is present, check for output voltage from

the transformer secondary. NOTE: this control

transformer outputs (2) secondary voltages: Red

Leads 29 VAC Brown Leads 10 VAC. If BOTH

secondary voltages are not present, replace the

transformer.

Conveyor will not run

Speed Adjustment

Potentiometer

This is a 0 to 50K ohm, 10 turn potentiometer.

WITH POWER OFF: remove the 3 pin

potentiometer cable plug from the motor control

board. With a digital multimeter, check the ohm

reading across the red lead to the black lead, this

reading should be 50K ohms ± 5% as the

potentiometer is rotated through its 10 turn rotation.

Place the meter leads on the red lead and white

lead. Rotating the potentiometer slowly, from low to

high, the meter should show an even transition

from 0 to 50K ohms ± 5% through the 10 turn

rotation of the potentiometer. There should be no

dead or open spots through the 10 turns of the

potentiometer. Check all three leads to ground.

There should be no continuity to ground. If any of

the above checks fail, replace the potentiometer.

Conveyor Motor(Stepper)

Control

NOTE: if the conveyor drive motor becomes

jammed or begins to run at an uncontrolled speed,

the conveyor motor will stop running. To reset, turn

off the conveyor switch, wait 30 seconds, turn the

conveyor switch on. If the motor does not run after

attempting re-set, check for 2 to 29 VAC across the

motor terminals 1 to 2 and 3 to 5 on, the conveyor

motor control. If voltage is not present at both sets

of terminals, replace control.