TROUBLESHOOTING GUIDE 1000 & 1200 SERIES / ELECTRIC OVENS

SYMPTOM

POSSIBLE CAUSE

EVALUATION

Incoming Power Supply

Check breakers/Reset if required/ Call Power Co. if

needed.

(Export Ovens)

For some export ovens, there is a control circuit

step-down transformer. This transformer steps

down supply voltage to 120 VAC. If main fan will

not run, the secondary of this transformer must be

checked for 120 VAC output. Check specific oven

model schematic for circuit location.

Oven Fan Fuse(s)

Check and/or Replace

Fuse Holder

Check and/or Replace

Fan Switch

Check continuity between switch terminals.

Main Relay

Check continuity to 120 VAC coil. Check for power

to the relay coil (120 VAC). Check for 208/220/240

VAC to relay terminals. Visually check for contact

pull-in

Fan Motor

Check for opens, shorts, or grounds. WITH POWER

OFF: Turn Fan Blade to check for locked rotor.

Oven fan will not run

NOTE:

Capacitor

Check for opens, shorts, or grounds.

No Main Fan Cool

Down

Cool Down Thermostat

Check cool down thermostat (thermostat closes at

160°F and opens at 140°F). Check for power (120

VAC) at cool down thermostat. With cool down

thermostat pre-heated, check for continuity. If

switch is open, replace.

Main Fan

Relay

Check for power to main fan relay. Visually check

for contact pull in.

No control box cooling

Axial Cooling Fan

WITH POWER OFF: turn the fan blade to check for

locked rotor. Check for power (120 VAC) to cooling

fan. If 120 VAC is present at the fan motor and the

fan does not run, replace fan assembly.

Main Oven Fan

Check if main oven fan is operating. If not, refer to

"Oven fan will not run."

Heat Switch

Check for continuity between switch terminals with

switch on. Replace if defective.

Air Pressure Switch

Check for 120 VAC on both sides of switch. If

voltage present on one side only, check for air tube

blockage, adjust air switch. If above fails, replace

air pressure switch.

Hi Limit Thermostat

Terminals are normally closed. If open, reset and

test oven for proper operation. If thermostat will not

hold for maximum oven temperature, and oven is

not exceeding temperature dial setting, replace

thermostat (rated at 190°F).

Hi Limit Thermostat

(Model 1032)

Terminals are normally closed. If open, reset and

test oven for proper operation. If thermostat will not

hold for maximum oven temperature, and oven is

not exceeding temperature dial setting. Replace the

thermostat. Check for proper location of sensing

bulb in its spring holder. If hi-limit is still tripping,

replace (rated for 368°C).

3 Amp Temperature Control

Fuse

Check and/or Replace

Oven will not heat

NOTE:

Fuseholder

Check and/or replace.