background image

Impinger I -–1000 Series Service Manual - International

38

Conveyor Drive

(Stepper) Motor

Perform all check as in the above evaluation. If the

time check is ok, refer to the next section. Check to

see if the conveyor drive (stepper) motor is running.

If motor is not running, refer to "Conveyor will not

run" on Page 35.

Magnet

Check to insure that the magnet (cemented to shaft

of conveyor drive (stepper) motor) has not been

damaged, or come loose from motor shaft. Replace

as needed. Hall Effect Sensor Check for any

physical damage to Hall Effect sensor(mounted on

conveyor drive(stepper)motor). Check all wiring

and connections for damage.

Time Display

inaccurate, erratic, or

inoperative(S/N

Q14975 & Above1000

Series) (S/N Q14791 &

Above1200 Series)

Conveyor Drive

(Stepper)Control

Check all connections for tightness or proper

location and check all wiring for visible damage.

Replace as needed. If there is still no time display,

wire in (temporarily) a new conveyor drive control.

If there is still no time display, reconnect original

conveyor drive control. Replace Hall Effect Sensor.

Advertising