Lincoln Impinger Conveyor Oven Series 1000 User Manual

Page 57

Advertising
background image

Impinger I -–1000 Series Service Manual - International

57

BURNER ASSEMBLY

1.

Shut off power at main breaker.

2.

Shut off gas supply.

3.

Remove control panel top and front panel.

4.

Remove gas control valve (See "GAS CONTROL VALVE")

5.

Disconnect pilot tube.

6.

Remove thermostat or solenoid valve.

7.

Remove four (4) phillips screws that secure the burner backing plate.

8.

Remove burner assembly from housing, the main and pilot orifice, flame target, pilot

shield (main and extension), flame sensor, and burner ignitor can now be changed or serviced as

needed.

9.

Reassemble in reverse order.

GAS CONTROL VALVE

Shut off power at main breaker.

Shut off gas supply.

Remove control panel top and front cover.

Disconnect the gas piping from the back of the unit.

Remove the four (4) screws from the incoming nipple mounting bracket.

Remove incoming nipple.

Remove pilot tube assembly from control valve.

Disconnect pipe union just above control valve.

Disconnect wiring from control valve making note of wire numbers and location.

Reassemble in reverse order - after assembly is complete be sure to check manifold pressure

(3.5" W.C. NAT Gas/10" W.C. LP) and adjust if necessary. (See Section

"MANIFOLD PRESSURE-ADJUSTMENT")

NOTE

: Check all gas line fittings for leaks after installation.

FRONT VIEW

MANIFOLD ADJUSTMENT
SCREW LOCATED UNDER
COVER SCREW

TOP VIEW

PILOT
LINE
CONNECTION

MANIFOLD PRESSURE
ADJUSTMENT CONNECTION

MANIFOLD ADJUSTMENT
SCREW LOCATED UNDER
COVER SCREW

MANIFOLD PRESSURE - ADJUSTMENT

1.

Remove control panel top and front cover.

2.

WITH ELECTRIC POWER AND GAS OFF: remove the outlet pressure tap plug from the gas