Chapter, Configuration using the web-based utility, Setup – Linksys SLM248G4S (G5) User Manual

Page 21: Setup > summary

Advertising
background image

Chapter 

Configuration Using the Web-based Utility

1

24/48-Port 10/100 + 4-Port Ggabt Reslent Clusterng Smart Swtch wth 2 Combo SFPs

Chapter :

Confguraton Usng the

Web-based Utlty

This chapter describes the features included in the

Web-based Utility. All features shown in this chapter,

unless specifically identified, are included in all Resilient

Clustering Smart Switches. Unique features for specific

Switches are noted.

NOTE:

The web-based utility is optimized for

a screen resolution of 1024 x 768. Internet

Explorer version 5.5 or above is required.

To use the utility, open your web browser, enter

http://192.18.1.24 in the Address field, then press Enter.

Address Bar

NOTE:

The default IP address is 192.18.1.24.

If you have changed the IP address or are using

DHCP to assign it, enter the new IP address

instead. The computer you use for configuration

should be on the same subnet as the Switch.

The Login screen appears. Enter admn in the Username

field and enter the password in the Password field. If this is

the first time you are using the utility, leave the Password

blank. Then press OK to log in. The Setup tab’s Summary

screen appears.
(After you have completed your first login, for security

purposes it is recommended that you set a password at

a later time. For detailed information on changing the

password, refer to section “Admin > User Authentication.”)

Login Screen

Each time you log in, the web-based utility first displays

the Setup tab’s Summary screen. To access another screen,

you first select the appropriate category from among

the 11 tabs that appear at the top of the screen: Setup,

Port Management, VLAN Management, Statstcs,

Securty, QoS, Spannng Tree, Multcast, SNMP, Admn,

and Logout. Then, select the desired screen from the list

directly below the tab names.

Setup

The Setup tab contains the Summary, Zoom, Network

Settings, Time, and Stack Management screens.

Setup > Summary

The Summary screen displays a summary of Switch

information. The settings shown cannot be modified

from the Summary screen; however, many of them can be

modified from the Setup tab’s Network Settings screen.

Setup > Summary

The Summary screen has two sections: Device Information

and System Information. These are described below.

Device Information

System Name

Displays the name of the Switch, if one has

been entered on the Setup tab’s Network Settings screen.

IP Address

The IP address assigned to the Switch. The

Switch’s default IP address is 192.18.1.24. This setting

can be configured from the Setup tab’s Network Settings

screen.

Subnet Mask

The Subnet Mask assigned to the Switch.

The default is 2.2.2.0. This setting can be

configured from the Setup tab’s Network Settings screen.

Advertising
This manual is related to the following products: