3 other bios error messages, Table8.3 other bios error messages, 4 other potential problems – LSI MegaRAID SCSI 320-2 RAID Controller Series 518 User Manual

Page 127: Table8.4 other potential problems, Other bios error messages, Other potential problems, Section 8.3, “other bios error messages, Section 8.4, “other potential problems

Advertising
background image

Other BIOS Error Messages

8-5

Copyright © 2002 by LSI Logic Corporation. All rights reserved.

8.3

Other BIOS Error Messages

Table 8.3

describes other BIOS error messages, their meaning, and

suggested solutions.

8.4

Other Potential Problems

Table 8.4

describes other potential problems.

Table 8.3

Other BIOS Error Messages

Message

Problem

Suggested Solution

Following SCSI disk
not found and no
empty slot available
for mapping it

The physical disk roaming
feature did not find the
physical disk with the
displayed SCSI ID. No slot is
available to map the physical
drive. MegaRAID cannot
resolve the physical drives
into the current configuration.

Reconfigure the array.

Following SCSI IDs
have the same data y,
z
Channel x: a, b, c

The physical drive roaming
feature found the same data
on two or more physical drive
on channel x with SCSI IDs a,
b, and c. MegaRAID cannot
determine the drive that has
the duplicate information.

Remove the drive or drives that should not
be used.

Unresolved
configuration
mismatch between
disks and NVRAM on
the adapter

The configuration stored in the
MegaRAID NVRAM does not
match the configuration stored
on the drives.

1. Press a key to run MegaRAID Manager.
2. Select View/Add Configuration from the

Configure menu.

3. Use View/Add Configuration to examine

both the configuration in NVRAM and the
configuration stored on the disk drives.

4. Resolve the problem by selecting one of

the configurations.

Table 8.4

Other Potential Problems

Topic

Information

DOS ASPI

MEGASPI.SYS, the MegaRAID DOS ASPI manager, uses 6 Kbytes of system
memory once it is loaded.

Advertising