2 recommended memory vendors, 4 step 4: check jumper settings, Table6.2 jumpers for the megaraid scsi 320-2 – LSI MegaRAID SCSI 320-2 RAID Controller Series 518 User Manual

Page 77: Step 4: check jumper settings

Advertising
background image

Installation Steps

6-5

Copyright © 2002 by LSI Logic Corporation. All rights reserved.

6.

You can now add or remove DRAM modules from the MegaRAID
controller, as described above.

7.

Reattach the battery pack harness to J10 on the MegaRAID
controller.

8.

Reinstall the MegaRAID controller in the computer. Follow the
instructions in this chapter.

9.

Replace the computer cover and turn the computer power on.

6.2.3.2

Recommended Memory Vendors

Call LSI Logic Technical Support at 678-728-1250 for a current list of
recommended memory vendors.

6.2.4

Step 4: Check Jumper Settings

Make sure the jumper settings on the MegaRAID SCSI 320-2 card are
correct. The jumpers are set at the factory and you probably do not need
to change them.

Table 6.2

lists the jumpers that you should check.

Figure 6.2

shows the location of these items on the MegaRAID SCSI

320-2 controller.

Table 6.2

Jumpers for the MegaRAID SCSI 320-2

Item

Description

Type

J2

SCSI activity LED connector

4-pin header

J3

Write pending indicator

2-pin header

J4

SCSI Termination Enable Channel 0

3-pin header

J5

SCSI Termination Enable Channel 1

3-pin header

J10

Battery connector

3-pin header

J16

BIOS Enable

2-pin header

J17

Termination Power Channel 0

2-pin header

J18

Termination Power Channel 1

2-pin header

Advertising