6. Connect the mini SAS signal cables to the RAID controller.

Note: Use the 400 mm (15.75 inches) mini SAS signal cable.

Figure 48. Connecting the mini SAS signal cables to the RAID controller

1

Ports 0-3

2

Ports 4-7

a. For one mini SAS signal cable, connect the end to the ports 0-3 on the RAID controller.

b. For the other mini SAS signal cable, connect the end to the ports 4-7 on the RAID controller.

7. Position the RAID controller near the riser card assembly. Ensure that the left edge of the RAID controller

is inserted into the notch of the RAID card retention bracket

1

, and then firmly insert the RAID controller

straight down into the PCI card slot 1

2

until it is securely seated. Then install the screw

3

to secure the

RAID controller.

Figure 49. Installing the RAID controller into the PCI card slot 1 on the riser card assembly

Note: There are three PCI card slots on the riser card assembly as shown in the illustration. The PCI
card slot 1

2

is for RAID cards only. For more information about the PCI card slots, see “Installing a

PCI card” on page 39.

8. Install the riser card assembly with the RAID controller into an appropriate PCI card slot on the system

board.

Chapter 5

.

Installing, removing, or replacing hardware

55