Serial port problems – Lenovo 1047 User Manual

Page 112

Advertising
background image

Symptom

Action

5. If you just installed an optional device, remove it, and restart the server. If

the server now starts, you might have installed more devices than the power
supply supports.

6. See “Solving undetermined problems” on page 102.

The server does not turn off.

1. Determine whether you are using an Advanced Configuration and Power

Interface (ACPI) or a non-ACPI operating system. If you are using a non-ACPI
operating system, do the following:

a. Press Ctrl+Alt+Delete.

b. Turn off the server by pressing the power-control button for 5 seconds.

c. Restart the server.

d. If the server fails the POST and the power-control button does not work,

disconnect the power cord for 20 seconds; then, reconnect the power cord
and restart the server.

2. If the problem remains or if you are using an ACPI-aware operating system,

suspect the system board.

The server unexpectedly shuts
down, and the LEDs on the
operator information panel are
not lit.

See “Solving undetermined problems” on page 102.

Serial port problems

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is

solved.

• See the parts listing in the Hardware Maintenance Manual to determine which components are customer

replaceable units (CRUs) and which components are field replaceable units (FRUs).

• If an action step is preceded by “(Trained service technician only),” that step must be performed only by

a trained service technician.

Symptom

Action

The number of serial ports that
are identified by the operating
system is less than the number
of installed serial ports.

1. Make sure that:

• Each port is assigned a unique address in the Setup Utility program and

none of the serial ports is disabled.

• The serial port adapter (if one is present) is seated correctly.

2. Reseat the serial port adapter.

3. Replace the serial port adapter.

A serial device does not work.

1. Make sure that:

• The device is compatible with the server.
• The serial port is enabled and is assigned a unique address.
• The device is connected to the correct connector.

2. Reseat the following components:

a. Failing serial device

b. Serial cable

3. Replace the following components one at a time, in the order shown, restarting

the server each time:

a. Failing serial device

b. Serial cable

c. (Trained service technician only) System board