Lexmark 4098-001 User Manual

Page 15

Advertising
background image

Diagnostic Information

2-3

4098-001

Note: There are seven reserved error code power light flashes (5,
10, 14, and 16
) that have no code names. If any reserved codes are
received, unplug and re-plug the printer.

8

None

NVRAM
error

Error detected in
reading or writing
NVRAM

Replace
system board.
See

“System

Board
Removal,”on
page 4-10

.

9

79

Error

xxxxx

Replace
system board.
See

“System

Board
Removal” on
page 4-10

.”

11

91

Error

xxxxx

Replace
system board

12

92

Short error

Short test
detected short
circuit in printhead

Check and
replace
printhead and
cable as
needed. If OK,
replace the
system board.

13

94

Head
Select

Install head ID and
print command
head ID do not
match

Replace
printheads.

15

96

USB error

Error in USB
hardware detected
or invalid result
occurred in USB
code

Check system
board cable. If
OK, check
system board
and power/
parallel/USB
board.
Replace as
needed.

None

31,32,33

Watchdog

No action

Number
of Power

Light

Flashes

Service
Error
(Logged)

Error
Name

Error Description

Action