Another available application

When 17 or more FP-X units need to be linked, the use of Modbus in-
stead of MEWNET-W0 (see above) can accommodate up to 99 FP-X
units. Because each FP-X can be a master or a slave, a multi-master link
can be constructed by passing a token from a user program.

Token passing (by user program)

Multi-master link of up

to 99 units is possible.

PLC link (MEWNET-W0)

Bit data/word data can be shared (linked) among up to 16 FP-X units. This is ideal for linking adjacent equipment in a distributed
control system.

Item

Specifications

Number of stations

16 stations

Transmission speed

115.2kbps

Transmission distance

1200m

Shared data

128 words (data register),

64 words (contacts)

Communication method

Floating master

Links with our other PLCs (FP

S (Sigma), FP2/FP2SH) are possible.

Simple setting of the number of linked units, linked relays
and starting area address of the own station by using FPWINPro
allows contact information and data to be shared without program-
ming.
Baud rate of 115.2kbps, the highest rate for a compact model.
A transfer distance of 1200m, the longest distance for a
compact model.
FP-X and FP

S (Sigma) allow a change of the station number by

programming (SYS instruction).



16 stations, 115.2 kbps, 1200m

RS485

Twisted-pair cable

FP-X requires a communication cassette (AFPX-COM3, AFPX-COM4 or AFPX-COM6)
FP2/FP2SH requires a multi-communication unit (FP2-MCU, FP2-CB485)
FP

S (Sigma) requires a communication cassette (FPG-COM3-A, FPG-COM4-A)

Different types of equipment need to be linked – FP-X flexibly meet such requirements.

Modbus-RTU compatibility

Compatible with both the master and slave of the Modbus RTU, the world’s de-facto standard. Great performance is expected for air-
conditioning, temperature control, etc.

Can also be used as
a slave station

Temperature

controller

Watt-hour meter

Inverter

FP-e

FP2

FP

3

Usable as a master station [F145 (SEND), F146 (RECV) commands]

Capable of easily communicating with a temperature controller, inverter, FP-e and foreign PLC

Up to 3 serial communication ports can be used simultaneously

Usable interfaces include RS232C, RS485, RS422 and USB.

* The RS232C tool port can be used as a general-purpose serial communication port.

Network

Communication cassette (two-channel type)

AFPX-COM2 (RS232C + RS232C)
AFPX-COM4 (RS485 + RS232C)
AFPX-COM5 (Ethernet + RS232C)
AFPX-COM6 (RS485 + RS485)

COM1: RS232C, RS485, Ethernet
COM2: RS232C, RS485, USB (The cassette port and the USB port cannot be used simultaneously.)
Tool port: RS232C