5. Diagnostics

8335-A2-GB20-70

February 2003

5-17

Table 5-5.

Diagnostics – Loopback Test

Loopback Test Screen – Model 8385

D-F

Displays the results of a loopback test.

Port Name – Select the name of the port to be tested (dsl1:1 through dsl24:1 on the
Model 8385).

Unit ID – Enter the unit to be tested in the SHDSL span:

STU-C for the central site SHDSL transceiver unit

STU-R for the remote site SHDSL transceiver unit

SRU-1 – SRU-8 for a Signal Transceiver Unit (repeater)

Serial No. – Displays the serial number of the unit to be tested after you enter the port
name and unit ID.

Unit Side – Enter the side of the unit to be tested (Customer or Network).

Duration – Enter the duration of the test (1–10 minutes) in 1-minute increments.

Test – Enter Start to begin the test. Enter Stop to end the test before the duration entered
has expired.

Total Tests Active – Displays the number of tests active on the card.

No of Repeaters in Loop – Displays the number of repeaters (SRUs) in the loop under
test.