[Reference]

Reference

command

1

mode

1

Setting of RS232C protocol parameters

Received data

3

axis

T1
T2

checksum

1

1

RTY

M/S

Error code

Transmitted data

Setting of the previous protocol parameters remains valid until execution of this command completes. The updated parameter setting will be

valid from a next command after execution of this command.

M/S=0 indicates "SLAVE" mode, while M/S=1 indicates "MASTER".

The RTY code is 4 bit and M/S is 1 bit.

Unit of T1 and T2 are 0.1 second and 1 second, respectively.

bit7

0 : Normal
1 : Error

6

5

Command error

4

3

RTY error

2

T2 error

1

T1 error

0

M/S error

1

axis

Error code

checksum

1

1

command

0

mode

5

Readout of the driver model name

Received data

0

axis

checksum

0

5

Error code

Transmitted data

The driver model name is 12 characters and transmitted by ASCII code.

ex. "MKDET1505 "

bit7

0 : Normal
1 : Error

6

5

Command error

4

3

2

1

0

0Dh
axis

Driver Model Name (high order)

Driver Model Name (low order)

Error code

checksum

0

5

command

0

mode

6

Readout of the motor model name

Received data

0

axis

checksum

0

6

Error code

Transmitted data

The motor model name is 12 characters and transmitted by ASCII code.

ex. "MUMA012P1 "

bit7

0 : Normal
1 : Error

6

5

Command error

4

3

2

1

0

0Dh
axis

Motor Model Name (high order)

Motor Model Name (low order)

Error code

checksum

0

6