Reference, Environment, Power – Panasonic AC Servo MINAS E Series IMC80A User Manual

Page 27: Circuit breaker, Peripheral equipment

Advertising
background image

181

[Reference]

Reference

Peripheral Equipment

Environment

The servo driver should be used under Contamination Level 2 or 1 specified by IEC60664-1 (housing the driver in

an IP54 control box).

Control box

Controller

Power supply for
insulated type
interface

Power

Insulating

transformer

Circuit

breaker

Leakage

breaker(RCD)

Surge

absorber

Noise filter

Noise filter for
signal lines

Protective earth (PE)

L1

U

CN X5

CN X1

CN
X3

CN X4

M

RE

V

W

E

L2
L3

Noise filter for
signal lines

AC servo

driver

AC servo
driver

Power

Single-phase 100V: Single-phase 100V

to 115V

50/60Hz

Single-phase 200V: Single-phase 200V

to 240V

50/60Hz

Three-phase 200V: Three-phase 200V

to 240V

50/60Hz

(1) Use under the environment of Over-voltage Category II specified by IEC60664-1

In order to realize the environment of overvoltage category II, install in the power supply input unit an insulating

transformer that is compliant with ICE or EN standard (EN 60742).

(2) The power for interface should be marked CE or appropriate EN Standard type (EN60950), 12VDC to 24VDC,

insulated.

Circuit Breaker

Install a circuit breaker between the power supply and noise filter. The circuit breaker should be IEC Standard and

UL listed

marked.

+ 10%

- 15 %

+ 10%

- 15 %

+ 10%

- 15 %

+ 10%

- 15 %

+ 10%

- 15 %

+ 10%

- 15 %

Advertising