Reference – Panasonic AC Servo MINAS E Series IMC80A User Manual

Page 19

Advertising
background image

173

[Reference]

Reference

command

8

mode

1

Individual writing of parameters

Received data

3

axis

Parameter No.

Parameter value L

H

checksum

8

1

Error code

Transmitted data

This command just changes a parameter temporarily. If you wish to write to EEPROM, execute writing to EEPROM of

parameter (mode=4)

Be sure to set 0 to unused parameters. Otherwise, data error will occur.

bit7

0 : Normal
1 : Error

6

Data error

5

Command error

4

Data error

Command error

3

No. error

2

1

0

1

axis

Error code

checksum

8

1

command

8

mode

4

Writing of parameters to EEPROM

Received data

0

axis

checksum

8

4

Error code

Transmitted data

This command is used to write a set parameters to EEPROM.

Transmission data will be returned after completion of EEPROM writing.

Writing to EEPROM may take approx. 5 seconds max. (if all parameters are changed).

When writing of parameters fails, data error will occur.

When control power supply LV is detected, control LV of error code will be returned, and parameter writing will be disabled.

Control LV

bit7

0 : Normal
1 : Error

6

5

4

3

2

1

0

1

axis

Error code

checksum

8

4

command

8

mode

0

Individual readout of parameters

Received data

1

axis

Parameter No.

checksum

8

0

Error code

Transmitted data

bit7

0 : Normal
1 : Error

6

5

Command error

4

3

No. error

2

1

0

3

axis

Parameter value L

H

Error code

checksum

8

0

Advertising