Alarm functions, When alarm arises – Panasonic WV-NS324 User Manual

Page 53

Advertising
background image

Pixel

numbers

-54-

When alarm arises, the camera performs output func-
tions according to the setup.

Inputs:

• Input from ALARM IN 1 and ALARM IN 2.
• Input from the built-in VMD (Video Motion Detector)

that detects motion in video by monitoring a speci-
fied area.

Outputs:

• The message "Alarm" is displayed in the upper

right corner of the Main Menu, Camera

C

ontrol win-

dow and Alarm List.

• The picture files of alarm events are stored in the

camera.

• An e-mail notifies the specified addresses of the

alarm activation with or without a picture file.

• The stored picture files are sent to the FTP server.
• The ALARM OUT terminal on the camera becomes

active.

• A notice of an alarm event is sent to the server

specified in the Panasonic Protocol Setup, using
Panasonic's original protocol.

When alarm arises

• The message "Alarm" is displayed in the upper

right corner of the Main Menu, Camera

C

ontrol win-

dow and Alarm List. The alarm status display may
be delayed for a maximum of half a minute due to
its refresh cycle.

• The pictures related to alarm events are stored in

the camera.
The number of pictures stored differs depending
on the pixel number, picture quality and the num-
ber of pre-alarm pictures stored. The oldest data
will be replaced by new picture data when the
memory capacity is exceeded. The table below
gives the number of pictures available for post-
alarm storage.

When the pre-alarm file is set to 20

When the pre-alarm file is set to none

• E-mail notifications can be sent to a maximum of

four addresses, with or without attached picture
file.
A mail contains: the camera name, time & date of
occurrence, cause of event, and the reference
addresses to the stored pictures as follows.

Number of stored alarm pictures: e.g., 324
URL of the picture: http//(Camera IP address)/
ALMxxxx_00.jpg

Notes:

• "xxxx" stands for the event number, and "00" for the

picture number.

• A picture numbered "00" will be automatically

attached to the mail.

• Enter "39" instead of "00" in the address bar if you

wish to view #40 picture.

• There may be cases where you cannot access the

images notified by the mail when new alarm activa-
tions took place after having sent the mail.

• The alarm picture number is updated during

recording.

• Alarm pictures and recording log are deleted when

the power is turned off.

• The Alarm List number is updated as alarm pic-

tures are to the set number.

ALARM FUNCTIONS

640 x 480

640 x 240

320 x 240

Super fine

113

247

514

160 x 120

514

Picture quality

Fine

165

351

722

722

Normal

210

440

901

901

LOW

242

451

922

922

Pixel

numbers

640 x 480

640 x 240

320 x 240

Super Fine

Picture quality

133

267

534

160 x 120

534

Fine

185

371

742

742

Normal

230

460

921

921

LOW

262

471

942

942

Advertising