Viewing rmon statistics, Table 44 rmon insert alarm dialog box fields, Alarm manager dialog box fields – Panasonic 470 User Manual

Page 103

Advertising
background image

RMON Alarms

103

Alarm Manager dialog box fields

Table 44
Rmon Insert Alarm dialog box fields

Field

Description

Variable

Name and type of alarm--indicated by the format:

alarmname.x where x=0 indicates a chassis alarm.

alarmname. where the user must specify the index. This is a card number for
module-related alarms, an STG ID for spanning tree group alarms (the default
STG is 1, other STG IDs are user-configured), or the Ether Statistics Control
Index for RMON Stats alarms.

alarmname with no dot or index is a port-related alarm and results in display of
the port selection tool.

Sample Type

Can be either absolute or delta.

For more information about sample types, refer to

"Creating alarms" (page

100)

.

Sample Interval

Time period (in seconds) over which the data is sampled and compared with
the rising and falling thresholds.

Index

Uniquely identifies an entry in the alarm table. Each such entry defines a
diagnostic sample at a particular interval for an object on the device.

Threshold Type

Rising Value

Falling Value

Value

When the current sampled value is
greater than or equal to this threshold,
and the value at the last sampling
interval is less than this threshold, a
single event is generated.

When the current sampled value is
less than or equal to this threshold,
and the value at the last sampling
interval is greater than this threshold,
a single event is generated.

Event Index

Index of the event entry used when a
rising threshold is crossed. The event
entry identified by a particular value
of this index is the same as identified
by the same value of the event index
object. (Generally, accept the default
that is already filled in.)

Index of the event entry used when
a falling threshold is crossed. The
event entry identified by a particular
value of this index is the same as
identified by the same value of the
event index object. (Generally,
accept the default that is already filled
in.)

Viewing RMON statistics

To view the RMON statistics and history for the port for which you have
created an alarm:

Nortel Ethernet Switch 460/470

Configuration — System Monitoring

NN47210-503

01.01

Standard

3.7

22 February 2007

Copyright © 2005-2007, Nortel Networks

Nortel Networks Confidential

.

Advertising