Logging remote level command, No logging remote level command – Panasonic 470 User Manual

Page 38

Advertising
background image

38

Chapter 2 Configuring network monitoring using CLI

The

no logging remote address

command has no parameters or

variables.

logging remote level command

The

logging remote level

command sets the severity level of the

logs you send to the remote server. The syntax for the

logging remote

level

command is:

logging remote level {critical | informational | serious}

The

logging remote level

command is in the config command mode.

Table 11 "logging remote level command parameters and variables" (page
38)

describes the parameters and variables for the

logging remote

level

command.

Table 11

logging remote level

command parameters and variables

Parameters and
variables

Description

{critical | serious |
informational}

Specifies the severity level of the log messages sent
to the remote server:

critical

informational

serious

There is no default value for this command.

no logging remote level command

The

no logging remote level

command removes any severity level of

the log messages that you send to the remote server; it reverts to None.
The syntax for the

no logging remote level

command is:

no logging remote level

The

no logging remote level

command is in the config command

mode.

The

no logging remote level

command has no parameters or

variables.

Nortel Ethernet Switch 460/470

Configuration — System Monitoring

NN47210-503

01.01

Standard

3.7

22 February 2007

Copyright © 2005-2007, Nortel Networks

Nortel Networks Confidential

.

Advertising