Electrical Components
The electrical components are located on the power base. The main circuit breaker is located toward the rear of

the power base. The controller connector is located on the rear of the power base. See figure 6.

Controller Connector: This is where the controller connects to the power base. Each controller uses a different

type of harness. Regardless of which type of controller is used, the harness must be secured to the seat assembly

and not allowed to drag on the floor.

Main Circuit Breaker: The main circuit breaker is a safety feature built into your power chair. When the batteries

and the motors are heavily strained (e.g., from excessive loads), the main circuit breaker trips to prevent damage

to the motors and the electronics. If the circuit trips, allow your power chair to “rest” for approximately one

minute. Next, push in the circuit breaker button, turn on the controller, and continue normal operation. If the main

circuit breaker continues to trip repeatedly, contact an authorized Pride Provider.