Vii. care and maintenance – Pride Mobility Jazzy Select Series User Manual

Page 33

Advertising
background image

Select Traveller

www.pridemobility.com

33

7. Reconnect the battery strap making sure the battery harnesses are secured under the battery strap.

8. Reinstall the battery cover by aligning the tabs as shown in figure 17 and pressing down.

When to See Your Authorized Pride Provider for Service
The following symptoms could indicate a serious problem with your power chair. If necessary, contact your

authorized Pride Provider. When calling, have the model number, serial number, nature of the problem, and the

error code if available.

Motor noise

Frayed harnesses

Cracked or broken connectors

Uneven wear on any of the tires

Jerky motion

Pulling to one side

Bent or broken wheel assemblies

Does not power up

Powers up, but does not move

Corrective Maintenance
If the battery condition meter does not light up when you turn on the power:

Check the harness connections. Make sure they are tight.

Check the circuit breaker. Reset it if necessary.

Check the battery connections.

If the above conditions prove normal, you can load test the batteries with a battery load tester. These testers are

available at automotive parts stores. Disconnect both batteries before load testing and follow the directions that

come with the load tester. If either one of the batteries fails the load test, replace both of them. If your power chair

still does not power up, contact your authorized Pride Provider.

V I I . C A R E A N D M A I N T E N A N C E

You may need the following to replace your

batteries:

metric/standard socket set and ratchet

adjustable wrench

To replace the batteries:

1. Lift up on the battery cover and slide the tabs out

as shown in figure 17.

2. Disconnect the battery strap.

3. Remove the red (+) positive and black (-) negative

battery harness from each battery.

4. Remove the batteries.

5. Place the new batteries into the battery wells with

the terminals facing out as shown in figure 18.

6. Reconnect the two battery harnesses to the battery

terminals. Make sure the red harness is connected

to the (+) positive terminal and the black harness

is connected to the (-) negative terminal on each

battery.

Figure 18. Battery Orientation

- +

+ -

Advertising