Function menus

<50P IN/OUT ASSIGN>

50-pin assignment factory settings

Pin
no.

I/O

Setting item

1

I

REC

2

I

PLAY

3

I

FF

4

I

REW

5

I

STOP

6

I

___

7

I

___

8

I

422 REMOTE ON

9

I

422 REMOTE OFF

10

I

LOCAL ENABLE

11

I

EJECT

12

I

IN SET

13

I

REC INH ALL

14

I

REC INH PRE

15

I

LOCAL DISABLE

16

I

TC EXT

17

I

TC INT&TCG MODE AUTO

18

I

___

19

I

___

20

I

STNDBY ON/OFF

21

O

ERR0 STATUS

22

I

DET STOP ON

23

I

CUE

24

O

ERR1 STATUS

25

I

DET STOP OFF

26

Power

27

O

REC STATUS

28

O

PLAY STATUS

29

O

FF STATUS

30

O

REW STATUS

31

O

STOP STATUS

32

O

422 REMOTE STATUS

33

O

EJECT STATUS

34

O

ERR2 STATUS

35

O

TC SRC1 STATUS

36

O

TC SRC2 STATUS

37

O

___

38

O

___

39

O

REC INH1 STATUS

40

O

REC INH2 STATUS

Pin
no.

I/O

Setting item

41

O

CUE STATUS

42

O

REMOTE STATUS

43

O

DET STOP STATUS

44

O

PRE CTL DETECTED STATUS

45

O

LOCAL ENABLE STATUS

46

O

STANDBY ON STATUS

47

GND

48

O

___

49

GND

50

GND

“__” denotes that nothing is subject to control or to a status.

50P IN/OUT
ASSIGN

<Notes>
• For a command, input TTL level signals; for an

active low edge, input an electrical signal of 100 ms
or more.

• For a status, a maximum open collector and sink

current of 6 mA is output.

Advertising