6. Remove the old tube from the pneumatic tire and replace it with a new tube.

7. Slide the wheel back onto the shaft.

8. Reinstall the drive wheel nut into the center hub and tighten.

9. Inflate the pneumatic tire to 30 - 35 psi.

10. Remove the power chair from the blocks.

Battery Replacement

A diagram is printed on a decal located on the Jazzy frame near the battery tray. See figure 27.

WARNING! Battery posts, terminals, and related accessories contain lead and lead compounds.

Wear goggles and gloves when handling batteries and wash hands after handling.

WARNING! Pride Power Chair batteries are heavy. See specifications table. If you are unable to

lift that much weight, be sure to get help. Lifting beyond your capacity can result in personal

injury.

To replace the batteries:

1. Turn the power off.

2. Make sure that the Jazzy is in drive mode. See IV. “The Jazzy 1101/1121.”

3. Remove the ball detent pin that secures the footrest to the frame. See figure 12.

4. Lift off the footrest.

5. Locate the battery quick disconnects on the frame and disconnect both of them. See figure 27.

6. Remove the batteries from the power base.

7. Disconnect the wiring harness from each battery.

8. Reinstall the wiring harnesses on each battery. Make sure that you connect the red wire to the positive (+) battery

terminal and the black wire to the negative (-) battery terminal. See figure 27.

WARNING! Make sure you tighten the fasteners so that the connections are secure.

9. Place the batteries back into the power base.

I X . C A R E A N D M A I N T E N A N C E

Figure 28. 1101/1121 Battery Wiring Diagram Label