Motor Service

1.

Protect from heat:

• Shade the motor and controller from the sun.
• Any enclosure must be well ventilated to prevent overheating. Particular attention should be paid

to the motor fan cover and the cooling fins between the drive and the motor.

• Provide ample cross ventilation.

2.

Protect against dirt:

• Protect from any foreign matter or splashing water.
• Do not store (or spill) pool chemicals near the motor.
• Avoid sweeping or stirring up dust near the motor while it is operating.
• If a motor has been damaged by dirt it voids the motor warranty.

3.

Protect against moisture:

• Protect from splashing pool water.
• Protect from the weather.
• Protect from lawn sprinklers.
• If a motor has become wet - let it dry before operating. Do not allow the pump to operate if it has

been flooded.

• If a motor has been damaged by water it voids the motor warranty.

Note: DO NOT wrap motor and controller with plastic or other air tight materials. The motor and

controller may be covered, but not wrapped in plastic, during a storm, for winter storage, etc., but

never when operating, or expecting operation.
When replacing the motor, be certain that the motor support is correctly positioned to support the

size of motor being installed.

Pump Strainer Basket Service

(Continued)

9. Ensure that the lid o-ring is properly placed. Seat the clamp and lid

then turn clockwise until the handles are horizontal as shown.

10. Reconnect the communication cable to the pump if required.
11. Switch the power ON at the circuit breaker. Reset the pool time

clock to the correct time.

WARNING — FILTER OPERATES UNDER HIGH PRESSURE. WHEN

ANY PART OF THE CIRCULATING SYSTEM (e.g., LOCK RING,
PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER
THE SYSTEM AND BECOME PRESSURIZED. PRESSURIZED
AIR CAN CAUSE THE LID TO BLOW OFF WHICH CAN RESULT IN
SEVERE INJURY, DEATH, OR PROPERTY DAMAGE. TO AVOID

THIS POTENTIAL HAZARD, FOLLOW THESE INSTRUCTIONS.

12. Open the manual air relief valve on top of the filter.
13. Stand clear of the filter. Press the Start button on the pump.
14. Bleed air from the filter until a steady stream of water comes out.
15. Close the manual air relief valve.