VS Troubleshooting Problems

Use the following general troubleshooting information to resolve possible problems with your IntelliFlo

®

VS pump.

Note: Switch the main power off to the pump before attempting service or repair.

Problem

Possible Cause

Corrective Action

Pump failure. Refer to

Alarm and warning LED

sequence.

Pump will not prime - Air leak in suction.

Pump will not prime - Not enough water.

Pump strainer clogged.

Pump strainer gasket defective.

Check suction piping and valve glands

on any suction gate valves.

Secure lid on pump strainer pot and

make sure lid gasket is in place.

Check water level to make sure skimmer

is not drawing air.

Ensure that the suction lines, pump,

strainer, and pump volute are full of

water.

Clean pump strainer pot.

Replace gasket.

Reduced capacity and /

or head.

Refer to Alarm and

warning LED sequence.

Air pocket or leaks in suction line.

Clogged impeller.

Pump strainer clogged.

Check suction piping and valve glands

on any suctin gate valves.

Turn off electrical power to the pump.

Remove the (6) bolts that holds the vo-

lute to the seal plate.

Slide the motor and seal plate away from

the volute.

Clean debris from impeller. If debris can-

not be removed, complete the following

steps.

1. Remove diffuser and o-ring.

2. Remove left hand thread anti-spin bolt

and o-ring.

3. Remove, clean and reinstall impeller.

4. Reinstall anti-spin bolt and

o-ring.

Reinstall diffuser, and o-ring.

Reinstall motor and seal plate into volute.

Reinstall (6) bolts around seal plate and

volute and tighten securely.

Clean suction trap.