Problems and Corrective Action

(Continued)

Problem

Possible Cause

Corrective Action

Circuit breaker trips

repeatedly.

Refer to Alarm and

warning LED

sequence .

Excessive motor current.

GFCI fault.

Breaker must be of adequate

capacity. For GFCI breaker,

test according to GFCI manu-

facturer’s instructions.

Be sure no other lights and ap-

pliances are on circuit. Voltage

too high or too low.

Electrical problem.

Refer to Alarm and

warning LED

sequence.

Pump may be too hot.

Check line voltage; if less

than 90% or more than 110%

of rated voltage consult a

licensed electrician.

Increase ventilation.

Reduce ambient temperature.

Tighten any loose wiring con-

nections.

Motor internal terminal over-

load protector is open.

Motor runs too hot. Turn power

to motor off.

Check for proper voltage.

Check for proper impeller or

impeller rubbing.

Mechanical Troubles

and Noise.

The pump motor is running but with loud noise.

Cavitation.

If suction and discharge pip-

ing are not adequately sup-

ported, pump assembly will be

strained. Do not mount pump

on a wooden platform! Secure-

ly mount on concrete platform

for quietest performance. For-

eign matter (gravel, metal, etc.)

in pump impeller. Disassemble

pump, clean impeller, follow

pump service instructions for

reassembly.

Improve suction conditions.

Increase pipe size. Decrease

number of fittings. Increase

discharge pressure.