8.4.35 Engaging and disengaging the motor brake

COMPAX controls the idle holding brake of the motor and final stage. The time
behaviour can be set using P17 and P211 Bit 2.

If you are using an axis which is under torque when idle (e.g. when using a z axis),
the drive can be engaged and disengaged in a manner which ensures that the load
does not move. To do this, the drive remains powered during the reaction time of
the idle holding brake. This can be set using P17 (see following diagrams).

Final stage blocked by:

error or

OUTPUT O0="1" or

emergency STOP.

The final stage is enabled via:

quit or

OUTPUT O0="0" or

once Power is on

with P211 Bit 2="0".

The final stage is enabled
via:

OUTPUT O0="0"

P211 Bit 2="1"
(the lag of 0.5s is switched off)

P17=0

t

disabled

power out-
put stage
enable

t

de-energised

t

close

brake
open

energised

t

t

t

0,5s

disabled

power out-
put stage
enable

de-energised

close

brake
open

energised

t

t

t

disabled

power out-
put stage
enable

de-energised

close

brake
open

energised

P17>0

t

t

t

P17

disabled

power out-
put stage
enable

de-energised

close

brake
open

energised

t

disabled

power out-
put stage
enable

t

de-energised

energised

t

close

brake
open

0,5s

P17

t

t

t

P17

disabled

power out-
put stage
enable

de-energised

close

brake
open

energised

Meaning

Unit

Min. Value

Standard

Maximum value

Applies to ...

Braking delay

ms

0

0

500

VP

Application:

Range of values
for P17: