8.6.1.2 Free assignment of inputs and outputs

You can make the permanently assigned standard inputs I1 to I6 available for
assignment using parameter P221. Meaning:

Input

Function without
SHIFT

Function with SHIFT

Valency

I1 (X8/1)

SHIFT

-

1

(Bit 1)

33

I2 (X8/2)

Manual+

Find machine zero (MZ)

2

(Bit 2)

I3 (X8/3)

Hand–

Approach real zero (RZ)

4

(Bit 3)

I4 (X8/4)

Quit

Teach real zero

8

(Bit 4)

I5 (X8/5)

START

reserved

16

(Bit 5)

I6 (X8/6)

STOP

Break (breaks off data
record)

32

(Bit 6)

Each input is assigned a valency. Calculate the sum of the valencies of the
required free inputs and enter this in parameter P221.

Hand+ and Hand- should be possible via the inputs; I1, I4, I5 and I6 should be
freely available.
1 (I1) + 8 (I4) +16 (I5) +32 (I6) = 57
You will obtain this setting using P221 = 57.

Note that when I1 is freely assigned (SHIFT), you can no longer
perform any "Functions with shift" via the inputs!

You can directly cancel all input functions (apart from Hand+ and Hand-) as
commands using interfaces (RS232, bus system).

The status outputs O1 to O6 can be freely assigned using parameter P225.

Use P223 and P224 to assign the outputs of the OUTPUT WORD command of

the bus systems (Interbus-S, Profibus, CAN – Bus, ...).

Use P245 and P246 to assign the outputs of the HEDA bus (COMPAX with IPM

via the option A1).

Permanently assigned outputs of unit variants (COMPAX XX30, ...) cannot be

masked.

RS232

Output x=y

bussystems

Output WORD

command line

bussystems

PLC data interface

HEDA via IPM

O1 ... O6
status outputs

or

1

O1 ... O6

O1 ... O6

O7 ... O11

O1 ... O16

O1 ... O16

O7 ... O11

0

0

0

1

1

1

P18

= "1" or "3"

O12 ... O16

O1 ... O16

P225

P223 /
P224

P245 /
P246

towards
outputs

33

Counting starts at 1.

Free assignment
of inputs

Setting P221

Example:

Free assignment
of outputs

Structural diagram