Monitoring and limitation characteristics, 3 monitoring and limitation characteristics, Appendix – Parker Products COMPAX-M /-S (L) User Manual

Page 222: Compax-m/s, Structural diagram

Advertising
background image

Appendix

COMPAX-M/S

Monitoring and limitation characteristics

222

10.3.3 Monitoring and limitation characteristics

This section examines the relationships of COMPAX monitoring and limitation characteristics in more detail:

device supervision

Motor supervision

power output stage supervision

rate determination

current limit

min [I

GS

, P107*P105,P16*P105]

current control with
power output stage

speed control

motor

Hardware

Software

Software

1,5*I

GS

1,1*I

Mnenn

I

Gnenn

E53

E53

E41

T

G

T

M

...

current actual value

current reference value

I

Unom.

: unit nominal current

I

UP

: unit peak current I

Mnom.

: motor nominal current

Dynamic monitoring:

In COMPAX, the nominal current value is limited to the smallest value of the following 3 quantities.

I

UP

:

unit peak current

P105 * P107:

nominal motor current (P105) * maximum pulse current permitted for the motor (P107)

P105 * P16:

nominal motor current (P105) * maximum permitted (user-set) torque (P16)

Static monitoring

This executes triple monitoring:
Unit monitoring

Using the unit-specific time constant T

G

, a current greater than

I

Unom.

is permitted for a specific period; E53 then switches the unit

off.

Motor monitoring

Using the time constant T

M

, a current greater than 1.1 * I

Mnom.

is

permitted for a specified period; E53 then switches the unit off.
T

M

is set so that the pulse current P107 can flow for the period set

in P108.

Final stage / short circuit monitoring

Absolute monitoring to 1.5 * I

UP

.

Structural
diagram:

Advertising