Compax 35xxm connector assignment, Compax 35xxs unit features, 4 compax 35xxm connector assignment – Parker Products COMPAX-M /-S (L) User Manual

Page 29: Compax 35xxm connector assignment 29

Advertising
background image

COMPAX 35XXS unit features

COMPAX 35XXM connector assignment

29

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error list

7.4.4 COMPAX 35XXM connector assignment

X13/1

Housing

X13/2

N2

X13/3

B2

X13/4

A2

X13/5

N1

X13/6

B1

X13/7

A1

X13/8

+5V

X13/9

N2/

X13/10 B2/

X13/11 A2/

X13/12 N1/

X13/13 B1/

X13/14 A1/

X13/15 GND

X10/1

I9

X10/2

I10

X10/3

I11

X10/4

I12

X10/5

I13

X10/6

I14

X10/7

I15

X10/8

I16

X10/9

O9

X10/10 O10

X10/11 O11

X10/12 O12

X10/13 O13

X10/14 O14

X10/15 O15

X10/16 O16

X9/1

+24V

X9/2

GND

X9/3

reserved

X9/4

reserved

X9/5

24V

X9/6

15-24V Emerg. stop*

X9/7

Housing

X14(15)/1

NC

X16/1

T-

X17/6

GND

X17/7

Sig.MN

X17/8

Sig. E2

X17/9

Sig. E1

X14(15)/2

RxC

X14(15)/3

TxC

X14(15)/4

RxD

X14(15)/5

TxD

X14(15)/6

RxC/

X14(15)/7

TxC/

X14(15)/8

RxD/

X14(15)/9

TxD/

X16/2

NC

X16/3

D-

X16/4

NC

X16/5

GND

X16/6

T+

X16/7

NC

X16/8

D+

X16/9

+24V

X1

7:

DA

-m

o

n

it

or

initiators

X1

4/X1

5:

HED

A

X1

6:

Ab

so

lu

te

en

c

o

der

X1

3:

Enc

o

de

r

X9

X1

0:

Input / output

I9...I16; O9...O16

X8/1

I1

X8/2

I2

X8/3

I3

X8/4

I4

X8/5

I5

X8/6

I6

X8/7

I7

X8/8

I8

X8/9

O1

X8/10

O2

X8/11

O3

X8/12

O4

X8/13

O5

X8/14

O6

X8/15

O7

X8/16

O8

X17/1

DA-channel 0

X18/-

0V

X18/+

24V

X11/4

DA-channel 2

X11/3

Override

X11/2

GND

X11/1

+24V

X11/5

DA-channel 3

X11/6

Override (old)

X11/7

Shield

X17/2

DA-channel 1

X17/3

Shield

X17/4

GND 24V

X17/5

+24V

(O

pti

on

D1)

X1

1

X1

8:

Fa

n

X8

:

Input / output

I1...I8; O1...O8

* can be parameterized

X1/2

V

PE
+LS
-LS

X21/1

+24 V

X21/2

0V

X6/2

RxD

X6/3

TxD

X6/4

DTR

X6/5

GND

X6/6

DSR

X6/7

RTS

X6/8

CTS

X6/9

+5V

X1/1

U

X1/3

W

PE

X23/3

Br'

+

X23/4

Br+

X1:
Motor

H

V

d

c

an

d

24V

for a

d

ditiona

l

CO

M

P

AX-M

X21:
Control
voltage

X6

:

RS23

2

X19/6

15-24V Emerg.stop

X19/7

24V

X19/8

reserved

X19/9

+24V

X1

9

X19/1

+24V

X19/2

GND

X19/3

Stand by P

X19/4

Stand by S

X19/5

+24V

X19/10

Enable

X19/11

Shield

X5: output bus systems

Assignment depends on
the bus system

X7: output bus systems

Assignment depends on
the bus system

X20/2

L2

X20/1

L1

X20/3

L3

PE

X20:
AC Supply

PE

X3/1

Bra

ki

ng

re

si

stance

X3/2

X22: Braking
resistance

X3/2

PE

X23/1

Br'

+

X23/2

Br-

X23:
Motor brake

+24V

0V

X12/1

Housing

X12/2

+8V

X12/3

NC

X12/4

REF-

X12/5

SIN-

X12/6

NC

X12/7

GND

X12/8

ST+

X12/9

+5 V

X12/10 TEMP

X12/11 COS-

X12/12 COS+

X12/13 SIN+

X12/14 REF+

X12/15 ST-

X12:

Res

o

lver / SinCos

The assignment of X12 does not apply for the S3 option.

Enable final stage