8.6 Interfaces

The COMPAX interfaces for data and status are digital inputs with an PLC data
interface, an RS232 interface and an optional bus interface (interbus S, CAN bus,
CANopen, profibus, CS31 or RS485).
The RS232 interface can be operated simultaneously with other interfaces.

8.6.1 Digital inputs and outputs

To control the program process, 16 inputs and 16 outputs are available (8 inputs
and 8 outputs with COMPAX 1000SL).

O7-O11 and I7-I11 are assigned when the PLC data interface is switched
on.

Input

Assignment

I1 (X8/1; X19/x)

SHIFT

I2 (X8/2; X19/x)

Manual+

I3 (X8/3; X19/x)

Hand–

I4 (X8/4; X19/x)

Quit

I5 (X8/5; X19/x)

START

I6 (X8/6; X19/x)

Stop (interrupts data record)

I7 (X8/7; X19/x)

Freely assignable in the standard unit.

I8 (X8/8; X19/x)

Freely assignable in the standard unit.

SHIFT I2

Find machine zero (MZ)

SHIFT I3

Approach real zero (RZ)

SHIFT I4

Teach real zero

SHIFT I5

reserved

SHIFT I6

Break (breaks off data record)

I9 (X10/1; X19/x)

Freely assignable in the standard unit.

I10 (X10/2; X19/x)

Freely assignable in the standard unit.

I11 (X10/3; X19/x)

Assigned when P232=4 (activates position adjustment);
otherwise free.

I12 (X10/4; X19/x)

Freely assignable in the standard unit.

I13 (X10/5; X19/x)

Freely assignable in the standard unit.

I14 (X10/6; X19/x)

Assigned when mark reference is activated (P35=1)
(activates mark reference); otherwise free.

I15 (X10/7; X19/x)

Fast start (can be activated using P18)

I16 (X10/8; X19/x)

Is assigned if mark reference is activated (P35=1) (mark
input); otherwise free.

The assignment of inputs on X19 applies only to COMPAX 1000SL.

I/O - assignment
of standard unit