Service d/a monitor / override, Service d/a monitor, Start-up manual – Parker Products COMPAX-M /-S (L) User Manual

Page 56: Compax-m / -s, 5 service d/a monitor / override, 6 service d/a monitor, Assignment of x11, Service d/a monitor / override 56

Advertising
background image

Start-up manual

COMPAX-M / -S

Service D/A monitor / override

56

7.9.5 Service D/A monitor / override

Assignment of X11

(not applicable for COMPAX 1000SL)

Pin

Assignment

1

+24V

2

Ground 24V

3

Override for speed reduction

4

Standard DA channel 2: 8 Bit, Ri=2.21k

;

5

Standard DA channel 3: 8 Bit, Ri=2.21k

;

6

Override; previous input for existing applications

Connector: Phoenix
MC1.5/7-ST-3.81

45

67

123

7

Screen

With COMPAX 1000SL, the override input is on X19/13 (see Page 53),
the Service D/A monitors on X17/1 und X17/2 (see Page 55).

(not applicable for COMPAX 1000SL)

X11/3

X11/2

1K

10K

+5V

GND

100%

0%

10K

100nF

X11/6

10K

Override-
Signal

The override input is read in a cycle of 100 ms.

You can continue to use the previous override connection for current applications.

X19/13

X19/14

10K

+5V

GND

100%

0%

10K

100nF

Override-

Signal

1K

The override input is read in a cycle of 100 ms.

Wiring of override with screened cables only

7.9.6 Service D/A monitor

The service D/A monitor gives you the option of outputting internal measurement
and intermediate parameters from COMPAX in the form of analogue voltage in the
range of

±

10V via X11 (X17 with COMPAX 1000SL) and visualizing these by

means of an oscilloscope. This provides you with a capable aid for making the unit
functions clear and qualifiable, especially during the start-up.
This function (which is available in all units) provides you with two analogue output
channels with a resolution of 8 bit and these are updated every 100 µs.

Override
connection

Override -
Connection for
COMPAX
1000SL

Note:

COMPAX

COMPAX 1000SL

Advertising