Cleaning and replacing the air filter, Replacing the lamp unit – Panasonic PT-AE900U User Manual

Page 29

Advertising
background image

Care

and

m

aintenance

E

NGLISH

-57

56-E

NGLISH

Cleaning and replacing the air filter

If the air filter becomes clogged with dust, the internal temperature of the
projector will rise, the TEMP indicator will illuminate and the projector’s
power will turn off (the TEMP indicator will flash after the power is turned off).
The air filter should be cleaned every 100 hours of use.

NOTE:
B Place the projector on top of a

soft cloth so that it will not
become scratched.

NOTE:
B Be sure to install the air filter

before using the projector. If
the projector is used without
the air filter installed, dust and
other foreign particles will be
drawn into the projector, and
malfunctions will result.

B If the dust cannot be removed

by cleaning, it is time to
replace the air filter. Please
consult your dealer.
Furthermore, if the lamp unit is
being replaced, replace the air
filter at this time also.

# Turn off the MAIN POWER

switch and disconnect the
power code plug from the wall
outlet.
Turn off the MAIN POWER switch
according to the procedure given
in “Turning off the power” on page
28 before disconnecting the
power code plug from the wall
outlet.

$ Gently turn the projector

upside down.

& Clean the air filter.

Use a vacuum cleaner to clean
off any accumulated dust.

' Install the air filter.

Air filter

% Remove the air filter.

Put your fingernails under the air
filter and pull the air filter out of
the projector.

Replacing the lamp unit

Warning

The lamp unit should only be
replaced by a qualified
technician.
When replacing the lamp, allow it
to cool for at least one hour
before handling it.
B The lamp cover gets very hot,

and touching it can cause burns.

Notes on replacing the lamp
unit

B The light generating lamp is

made of glass, so dropping it or
allowing it to hit hard objects may
cause it to burst. Be careful when
handling the lamp.

B Dispose of the removed old lamp

with the same care that would be
taken with a fluorescent light.

B A Phillips screwdriver is

necessary for removing the lamp
unit.

Lamp unit replacement
period

The lamp is a consumable product.
Even when the full life of the bulb has
not been exhausted, the brightness
of the light will gradually decline.
Therefore periodic replacement of
the lamp is necessary.
The intended lamp replacement
interval is 3 000 hours, but it is
possible that the lamp may need to
be replaced earlier due to variables
such as a particular lamp’s
characteristics, usage conditions and
the installation environment.
Early preparation for lamp
replacement is encouraged.
The lamp will automatically shut off
after approximately 10 minutes when
3 000 hours of use have been
reached because of a much greater
chance of it exploding after this time.

NOTE:
B The projector is not supplied

with a replacement lamp unit.
Please ask your dealer for
details. Lamp unit product
no.: ET-LAE900

CAUTION:
B Do not use any lamp unit other

than the one with the product
number indicated above.

NOTE:
B The usage hours explained

above are for when “LAMP
POWER” in the “OPTION”
menu has been set to “HIGH”
and when “DYNAMIC IRIS” in
the “PICTURE” menu has
been set to “ON”. When
“LAMP POWER” has been set
to “HIGH” and “DYNAMIC
IRIS” has been set to “OFF”,
the usage hours will be 2 000
hours. If “LAMP POWER” is
set to “LOW”, the brightness of
the lamp will be less and life of
the lamp can be extended.

B While 3 000 hours is the

intended replacement interval,
it is not a period of time
covered by warranty.

Advertising