Adding and replacing DC power supplies

29

Installing a DC Power Supply in an Ethernet Routing Switch 8000 Series Chassis

Removing and installing a power filler panel

A power filler panel maintains the proper cooling airflow in the 8000 Series
chassis. When you install a power supply in a bay for the first time, you must first
remove the power filler panel from the power bay. If you remove a power supply
from the chassis without replacing it, you must install a power filler panel.

To remove a power filler panel:

1

For the 8010co chassis, remove the bottom front bezel.

For instructions, see

“Removing the bottom bezel (8010co chassis)” on

page 28

.

2

Using a Phillips screwdriver, loosen the two captive screws that secure the
power filler panel to the chassis until the power filler panel disengages
(

Figure 4

and

Figure 5 on page 30

).

Figure 4 Removing a power filler panel: 8010co chassis

10416FA