Installing the power supply, Figure 10, Dc power supply power switch – Nortel Networks 8000 Series User Manual

Page 36: Installing the power

Advertising
background image

36

Adding and replacing DC power supplies

313070-E Rev 00

Installing the power supply

To install a DC power supply:

1

Make sure that the power switch is turned off (

Figure 10

).

Figure 10 DC power supply power switch

2

For the 8010co chassis, remove the bottom front bezel.

For instructions, see

“Removing the bottom bezel (8010co chassis)” on

page 28

.

3

Remove the filler panel from the power bay if necessary.

For instructions, see

“Removing and installing a power filler panel” on

page 29

.

4

If you are replacing a failed power supply, remove the failed supply.

For instructions, see

“Removing the DC power supply” on page 45

.

5

Grasp the handle of the new power supply.

Caution: Save the power filler panel in case you need to operate the
8000 Series chassis with a power supply removed.

10298FA

1 = On
2 = Off

2

1

-DC

+DC