Adding and replacing DC power supplies

313070-E Rev 00

12 Attach the negative voltage lead to the negative terminal on the power supply

inserting a lock washer between the crimp lug and each hex nut

Figure 18 on

page 41

.

13 Using a 7/16 in. hex wrench, tighten the hex nut on each terminal.

14 Attach the earth ground cable to the system or rack ground for your DC input

power source.

15 Firmly slide the power supply all the way into the bay (

Figure 19

and

Figure 20

).

16 Tighten the retaining screws until the power supply is seated firmly.

Figure 19 Tightening the retaining screws on the DC power supply: 8010co
chassis

Figure 20 Tightening the retaining screws on the DC power supply: 8006 and
8010 chassis

17 Attach the positive and negative terminal leads to the DC input power source

according to the proper safety and technical specifications for your 48 V
power distribution system.

10339FA

+DC

-DC